SMA SOLAR TECHNOLOGY AG SUNNY TRIPOWER STP 9000TL INVERTER

The Three-Phase Inverter – Not Only for Your Home…

OVERVIEW


At home with leading-edge technology and top yields: The Sunny Tripower PV plant 5 to 9 kW of power is setting new standards for home systems. It features an asymmetric multi-string and Optiflex technology to ensure the highest in flexibility while combining peak efficiency with the OptiTrac Global Peak system to generate the highest in yields. In addition to communication via the external Bluetooth-antenna, the PV plant comes with a direct Sunny Portal connection via SMA Webconnect as standard – and now for the first time without data loggers. The "small" Sunny Tripower also comes with integrated grid management functions and reactive power supply and is suitable for operation with a 30 mA RCD.


ECONOMICAL

• Maximum efficiency of 98%

• Shade management with OptiTrac Global Peak

• Active temperature management with OptiCool


FLEXIBLE

• DC input voltage of up to 1,000 V

• Integrated grid management functions

• Reactive power supply

• Module-tailored system design with Optiflex


COMMUNICATIVE

• SMA Webconnect Portal communication

• Bluetooth® communication

• Simple country configuration

• Multi-function relay as standard


SIMPLE

• Three-phase feed-in

• Cable connection without tools

• SUNCLIX DC plug-in system

• Integrated ESS DC switch-disconnector

• Easy wall mounting


SCALE


DOWNLOAD

SMA SYSTEM SOLUTIONS for the VDEcode of practice and the German Renewable Energy Act (EEG 2012) · As of December 2012

  • Type: Technical information
  • Language: International
  • Number: SYSTEMPOSTER-AEN125018
  • Version: 1.8

Mounting on wooden grounding - Installation restrictions for mounting Sunny Boy, Sunny Mini Central and Sunny Tripower to wood

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: HolzUnt-TI-en-12
  • Version: 1.2

Shade Management - Efficient Operation of Partially Shaded PV Systems with OptiTrac Global Peak

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: GlobalPeak-TI-en-12
  • Version: 1.2

Solar Power: 100% Self-Consumption Solution with the SMA Power Control Module SUNNY BOY / SUNNY TRIPOWER

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: ZE-PCM-TI-en-20
  • Version: 2.0

Technical Information - Capacitive Leakage Currents - Information on the design of transformerless inverters of type Sunny Boy, Sunny Mini Central, Sunny Tripower

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Ableitstrom-TI-en-25
  • Version: 2.5

Overvoltage Protection - Lightning Protection and Overvoltage Protection for Sunny Boy and Sunny Tripower

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: U_Schutz-TI-en-13
  • Version: 1.3

Technical Information - Plant Communication in Large-Scale PV Power Plants

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC-PO-TI-en-34
  • Version: 3.4

Parameter list for STP 5000TL-20 / 6000TL-20 / 7000TL-20 / 8000TL-20 / 9000TL-20 / 10000TL-20 / 12000TL-20

  • Type: Technical information
  • Language: International
  • Number: PARAMETER-HTML_STPTL-20_V10
  • Version: 1.0

Criteria for Selecting a Residual-Current Device - Use of Residual-Current Devices for SUNNY BOY, SUNNY ISLAND, SUNNY BOY STORAGE and SUNNY TRIPOWER

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: RCD-TI-en-44
  • Version: 4.4

Technical Information - Short-Circuit Currents - Information on short-circuit currents of SMA PV inverters

  • Type: Technical information
  • Language: International
  • Number: Iscpv-TI-en-17
  • Version: 1.7

Overview of the Rotary Switch Settings for SMA PV inverter, status 03/2018 - SUNNY BOY / SUNNY TRIPOWER

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Drehschalter-LD-TI-en-13
  • Version: 1.3

Technische Information - SunSpec®-Modbus®-Schnittstelle // Technical Information - SunSpec® Modbus® Interface

  • Type: Technical information
  • Language: International
  • Number: SunSpec_Modbus-de-en_V21
  • Version: 2.1

Technical Information - Temperature Derating SUNNY BOY / SUNNY TRIPOWER

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Temp-Derating-TI-en-15
  • Version: 1.5

Technical Information - Impedance at 175 Hz for PV Systems in France SUNNY BOY / SUNNY MINI CENTRAL / SUNNY TRIPOWER / SUNNY HIGHPOWER / FLX PRO

  • Type: Technical information
  • Language: International
  • Number: Impedanz-175Hz-TI-en-31
  • Version: 3.1

Technical Information - Circuit breakers - Dimensioning of Suitable Circuit Breakers for Inverters under PV-Specific Influences

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: LSS-TI-en-45
  • Version: 4.5

Technical information - SUNNY BOY / SUNNY BOY STORAGE / SUNNY MINI CENTRAL / SUNNY TRIPOWER - Overview of the compatibility between common grid configurations and SMA inverters

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Netzformen-TI-en-31
  • Version: 3.1

Medium-voltage Transformers - Important requirements for medium-voltage transformers for SUNNY BOY, SUNNY MINI CENTRAL and SUNNY TRIPOWER

  • Type: Technical information
  • Language: International
  • Number: MV-Trafo-SB_SMC_STP-TI-en-12
  • Version: 1.2

Technische Information - Modbus®-Schnittstelle // Technical Information - Modbus® Interface

  • Type: Technical information
  • Language: International
  • Number: SMA_Modbus-de-en_V24
  • Version: 2.4

Efficiency and Derating - SUNNY BOY / SUNNY BOY STORAGE / SUNNY TRIPOWER / SUNNY MINI CENTRAL / SUNNY HIGHPOWER

  • Type: Technical information
  • Language: International
  • Number: WirkungDerat-TI-en-46
  • Version: 4.6

STP 5000TL-20 / 6000TL-20 / 7000TL-20 / 8000TL-20 / 9000TL-20 - For England only: Compliance with G83/2

  • Type: Service instructions
  • Language: English (Worldwide)
  • Number: STP5-9TL-G83-SG-en-10
  • Version: 1.0

For Israel Only: Parameter Settings - SUNNY BOY / SUNNY MINI CENTRAL / SUNNY TRIPOWER according to document HS_131_2013 (SMA code: ILS220 & ILS233)

  • Type: Service instructions
  • Language: English (Worldwide)
  • Number: Israel-HS_131_2013-ILS220_ILS233-SG-en-13
  • Version: 1.3

Service Manual for Installers - SUNNY TRIPOWER 5000TL / 6000TL / 7000TL / 8000TL / 9000TL / 10000TL / 12000TL

  • Type: Service instructions
  • Language: English (Worldwide)
  • Number: STP5-12TL-20-SG-en-13
  • Version: 1.3

SUNNY BOY / SUNNY TRIPOWER - For Northern Ireland only: Compliance with G83-1-1

  • Type: Service instructions
  • Language: International
  • Number: UK-G83_1_1-GBS262-SG-en-12
  • Version: 1.2

Manufacturer’s Declaration - Response of PV inverters to a grid handicap in the form of high proportions of harmonic voltage distortion (THDV)

  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: HK_Beeinflussung-durch-THD_en_10
  • Version: 1.0

Manufacturer's Declaration for SUNNY TRIPOWER Inverters (STP 15000TL-10, STP 17000TL-10, STP 15000TLEE-10, STP 20000TLEE-10, STP 5000TL-20, STP 6000TL-20, STP 7000TL-20, STP 8000TL-20, STP 9000TL-20, STP 10000TL-20, STP 12000TL-20, STP 20000TL-30, STP 25000TL-30)

  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: HK_STPmitSMAGridGuard_en_11
  • Version: 1.1

Certificate of conformity NS protection VDE-AR-N 4105 - STP 12000TL-20

  • Type: Manufacturers Declaration
  • Language: International
  • Number: ZE_VDE-AR-N-4105-NA_U16-0389_STP12000TL-20-en-10
  • Version: 1.0

Certificate of Conformity self-generation unit VDE-AR-N 4105 - STP 5000TL-20

  • Type: Manufacturers Declaration
  • Language: International
  • Number: ZE_VDE-AR-N-4105-EZE_U16-0376_STP5000TL-20-en-10
  • Version: 1.0

Certificate of Conformity self-generation unit VDE-AR-N 4105 - STP 6000TL-20